| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Heatmiser Netmonitor 3.03 contains a hardcoded credentials vulnerability in the networkSetup.htm page with predictable admin login credentials. Attackers can access the device by using the hard-coded username 'admin' and password 'admin' in the hidden form input fields. |
| Improper Neutralization of Input During Web Page Generation (XSS or 'Cross-site Scripting') vulnerability in Gitea Gitea Open Source Git Server allows Stored XSS.This issue affects Gitea Open Source Git Server: 1.22.0. |
| Incorrect Authorization vulnerability in OpenText™ Operations Bridge Manager. The vulnerability could allows privilege escalation by authenticated users.This issue affects Operations Bridge Manager: 2023.05, 23.4, 24.2, 24.4. |
| An OS command injection vulnerability exists in the OptiLink ONT1GEW GPON router firmware version V2.1.11_X101 Build 1127.190306 and earlier. The router’s web management interface fails to properly sanitize user input in the target_addr parameter of the formTracert and formPing administrative endpoints. An authenticated attacker can inject arbitrary operating system commands, which are executed with root privileges, leading to remote code execution. Successful exploitation enables full compromise of the device. Exploitation evidence was observed by the Shadowserver Foundation on 2025-02-04 UTC. |
| OGP-Website installs prior git commit 52f865a4fba763594453068acf8fa9e3fc38d663 are affected by a type juggling flaw which if exploited can result in authentication bypass without knowledge of the victim account's password. |
| JM-DATA ONU JF511-TV version 1.0.67 uses default credentials that allow attackers to gain unauthorized access to the device with administrative privileges. |
| Dispatch's notification service uses Jinja templates to generate messages to users. Jinja permits code execution within blocks, which were neither properly sanitized nor sandboxed. This vulnerability enables users to construct command line scripts in their custom message templates, which are then executed whenever these notifications are rendered and sent out. |
| UsersController::edit in Cerebrate before 1.30 allows an authenticated non-privileged user to escalate their privileges (e.g., obtain a higher role such as admin) via the user-edit endpoint by supplying or modifying role_id or organisation_id fields in the edit request. |
| A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions < V2020 SP2 Update 5), SIMATIC Information Server 2022 (All versions < V2022 SP1 Update 2), SIMATIC PCS 7 V9.1 (All versions < V9.1 SP2 UC06), SIMATIC Process Historian 2020 (All versions < V2020 SP2 Update 5), SIMATIC Process Historian 2022 (All versions < V2022 SP1 Update 2), SIMATIC WinCC Runtime Professional V18 (All versions < V18 Update 5), SIMATIC WinCC Runtime Professional V19 (All versions < V19 Update 3), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges. |
| An improper input validation allows an unauthenticated attacker to achieve remote command execution on the affected PAM system by sending a specially crafted HTTP request. |
| Improper input validation in the Linux kernel mode driver for some Intel(R) Ethernet Network Controllers and Adapters before version 28.3 may allow an authenticated user to potentially enable escalation of privilege via local access. |
| SQL Injection vulnerability in parameter "w" in file "druk.php" in MegaBIP software allows unauthorized attacker to disclose the contents of the database and obtain administrator's token to modify the content of pages. This issue affects MegaBIP software versions through 5.13. |
| A user can reverse engineer the JWT token (JSON Web Token) used in authentication for Manager and API access, forging a valid NeuVector Token to perform malicious activity in NeuVector. This can lead to an RCE. |
| An Authentication Bypass Using an Alternate Path or Channel vulnerability in Juniper Networks Session Smart Router or conductor running with a redundant peer allows a network based attacker to bypass authentication and take full control of the device.
Only routers or conductors that are running in high-availability redundant configurations are affected by this vulnerability.
No other Juniper Networks products or platforms are affected by this issue.
This issue affects:
Session Smart Router:
* All versions before 5.6.15,
* from 6.0 before 6.1.9-lts,
* from 6.2 before 6.2.5-sts.
Session Smart Conductor:
* All versions before 5.6.15,
* from 6.0 before 6.1.9-lts,
* from 6.2 before 6.2.5-sts.
WAN Assurance Router:
* 6.0 versions before 6.1.9-lts,
* 6.2 versions before 6.2.5-sts. |
| NetSarang Xmanager Enterprise 5.0 Build 1232, Xmanager 5.0 Build 1045, Xshell 5.0 Build 1322, Xftp 5.0 Build 1218, and Xlpd 5.0 Build 1220 contain a malicious nssock2.dll that implements a multi-stage, DNS-based backdoor. The dormant library contacts a C2 DNS server via a specially crafted TXT record for a month‑generated domain. After receiving a decryption key, it then downloads and executes arbitrary code, creates an encrypted virtual file system (VFS) in the registry, and grants the attacker full remote code execution, data exfiltration, and persistence. NetSarang released builds for each product line that remediated the compromise: Xmanager Enterprise Build 1236, Xmanager Build 1049, Xshell Build 1326, Xftp Build 1222, and Xlpd Build 1224. Kaspersky Lab identified an instance of exploitation in the wild in August 2017. |
| A vulnerability, which was classified as very critical, was found in IROAD Dash Cam X5 and Dash Cam X6 up to 20250308. This affects an unknown part. The manipulation leads to improper authorization. It is possible to initiate the attack remotely. The vendor was contacted early about this disclosure but did not respond in any way. |
| Incorrect Implementation of Authentication Algorithm vulnerability in ABB ABB Ability OPTIMAX.This issue affects ABB Ability OPTIMAX: 6.1, 6.2, from 6.3.0 before 6.3.1-251120, from 6.4.0 before 6.4.1-251120. |
| WHILL Model C2 Electric Wheelchairs and Model F Power Chairs do not enforce authentication for Bluetooth connections. An attacker within range can pair with the device and issue movement commands, override speed restrictions, and manipulate configuration profiles without any credentials or user interaction. |
| Improper initialization in the Linux kernel mode driver for some Intel(R) Ethernet Network Controllers and Adapters before version 28.3 may allow an authenticated user to potentially enable escalation of privilege via local access. |
| Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability in Western Digital My Cloud ddns-start on Linux allows Overflow Buffers.This issue affects My Cloud: before 5.29.102. |