| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Cleartext Storage of Sensitive Information, Exposure of Sensitive Information Through Data Queries vulnerability in Finrota Netahsilat allows Retrieve Embedded Sensitive Data, Authentication Bypass, IMAP/SMTP Command Injection, Collect Data from Common Resource Locations.
This issue solved in versions 1.21.10, 1.23.01, 1.23.08, 1.23.11 and 1.24.03. |
| Echelon SmartServer 1 all versions, SmartServer 2 all versions prior to release 4.11.007, i.LON 100 all versions, and i.LON 600 all versions. The devices allow unencrypted Web connections by default, and devices can receive configuration and firmware updates by unsecure FTP. |
| Omron CX-One CX-Programmer before 9.6, CJ2M PLC devices before 2.1, and CJ2H PLC devices before 1.5 rely on cleartext password transmission, which allows remote attackers to obtain sensitive information by sniffing the network during a PLC unlock request. |
| Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an
unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an
attacker to impersonate a legitimate device and inject malicious
payloads. This enables the insertion of harmful code directly
into the Orca user portal, potentially compromising user accounts,
exposing sensitive information, and allowing further unauthorized
actions within the portal. |
| CodexBar prior to 0.32.0 contains a session cookie leakage vulnerability that allows network attackers to intercept imported browser session cookies by exploiting improper redirect handling for Amp and Ollama provider sessions. Attackers can position themselves on the network path to receive cleartext HTTP requests carrying imported session cookies when a provider-controlled redirect target issues a redirect to a cleartext HTTP endpoint within the same provider domain. |
| A vulnerability has been identified in SIMATIC HMI Comfort Panels 4" - 22" (All versions < V15.1 Update 1), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (All versions < V15.1 Update 1), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 und KTP900F (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Update 1), SIMATIC WinCC Runtime Professional (All versions < V15.1 Update 1), SIMATIC WinCC (TIA Portal) (All versions < V15.1 Update 1), SIMATIC HMI Classic Devices (TP/MP/OP/MP Mobile Panel) (All versions). An attacker with network access to affected devices could potentially obtain a TLS session key. If the attacker is able to observe TLS traffic between a legitimate user and the device, then the attacker could decrypt the TLS traffic. The security vulnerability could be exploited by an attacker who has network access to the web interface of the device and who is able to observe TLS traffic between legitimate users and the web interface of the affected device. The vulnerability could impact the confidentiality of the communication between the affected device and a legitimate user. At the time of advisory publication no public exploitation of the security vulnerability was known. |
| An insecure communication was found between a user and the Orpak SiteOmat management console for all known versions, due to an invalid SSL certificate. The attack allows for an eavesdropper to capture the communication and decrypt the data. |
| RustFS is a distributed object storage system built in Rust. Prior to 1.0.0-beta.2, RustFS suffers from sensitive information leakage in log outputs. When the server is run with RUST_LOG=debug sensitive credentials including SessionToken (JWT), SecretAccessKey, and full JWT claims are printed in plaintext to the server logs. This vulnerability is fixed in 1.0.0-beta.2. |
| A vulnerability was reported in Lenovo System Update that could allow a local user with interactive system access the ability to execute code with elevated privileges only during the installation of a System Update package released before 2022-02-25 that displays a command prompt window. |
| Cleartext Storage of Sensitive Information in a Cookie vulnerability in Oceanic Software ValeApp allows Protocol Manipulation, : JSON Hijacking (aka JavaScript Hijacking).
This issue affects ValeApp: before v2.0.0. |
| StrongDM Desktop Application before 23.74.0 (Desktop Client before 53.77.0) on Microsoft Windows stores authentication state, including a JSON Web Token and asymmetric key material, in cleartext in a per-user state file located at C:\Users\<username>\.sdm\state.kv. The file is protected only by default user-level NTFS permissions.
Exploitation requires local read access to the affected user's profile directory and additional deployment and execution conditions on the target host.
The condition was reported through coordinated disclosure by Hope Walker (SpecterOps). |
| Cleartext Storage of Sensitive Information in an Environment Variable, Weak Password Recovery Mechanism for Forgotten Password vulnerability in Tapandsign Technologies Tap&Sign App allows Password Recovery Exploitation, Functionality Misuse.
This issue affects Tap&Sign App: before V.1.025. |
| Cleartext Transmission of Sensitive Information in the SICK ICR890-4 could allow a
remote attacker to gather sensitive information by intercepting network traffic that is not encrypted. |
| Cleartext Storage on Disk in the SICK ICR890-4 could allow an unauthenticated attacker with local access to the device to disclose sensitive information by accessing a SD card. |
| Cleartext Storage of Sensitive Information in SICK FTMg AIR FLOW SENSOR with
Partnumbers 1100214, 1100215, 1100216, 1120114, 1120116, 1122524, 1122526 allows a remote
attacker to potentially steal user credentials that are stored in the user’s browsers local storage via
cross-site-scripting attacks. |
| A CWE-311: Missing Encryption of Sensitive Data vulnerability exists in Modicon M221 (all references, all versions) that could allow the attacker to find the password hash when the attacker has captured the traffic between EcoStruxure Machine - Basic software and Modicon M221 controller and broke the encryption keys. |
| A CWE-319: Cleartext transmission of sensitive information vulnerability exists in PowerLogic ION7400, ION7650, ION7700/73xx, ION83xx/84xx/85xx/8600, ION8650, ION8800, ION9000 and PM800 (see notification for affected versions), that could cause disclosure of user credentials when a malicious actor intercepts Telnet network traffic between a user and the device. |
| The password and username reset features created plain http links for https connections if the "Force SSL" flag wasn't explicitly set. |
| A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers. |
| The MD5 Message-Digest Algorithm is not collision resistant, which makes it easier for context-dependent attackers to conduct spoofing attacks, as demonstrated by attacks on the use of MD5 in the signature algorithm of an X.509 certificate. |