| The Clinician Password and Serial Number Clinician Password are hard-coded into the ventilator in plaintext form. This could allow an attacker to obtain the password off the ventilator and use it to gain unauthorized access to the device, with clinician privileges. |
| hippo4j 1.0.0 to 1.5.0, uses a hard-coded secret key in its JWT (JSON Web Token) creation. This allows attackers with access to the source code or compiled binary to forge valid access tokens and impersonate any user, including privileged ones such as "admin". The vulnerability poses a critical security risk in systems where authentication and authorization rely on the integrity of JWTs. |
| An unauthenticated remote attacker can use the hard-coded credentials to access the SmartSPS devices with high privileges.
|
| There are several scripts in the web interface that are accessible via undocumented hard-coded credentials. The scripts provide access to additional administrative/debug functionality and are likely intended for debugging during development and provides an additional attack surface. |
| An attacker with local access to the medical office computer can
access restricted functions of the Elefant Service tool by using a
hard-coded "Hotline" password in the Elefant service binary, which is shipped with the software. |
| An issue was discovered on ROADCAM X3 devices. It has a uniform default credential set that cannot be modified by users, making it easy for attackers to gain unauthorized access to multiple devices. |
| MinMax CMS from MinMax Digital Technology contains a hidden administrator account with a fixed password that cannot be removed or disabled from the management interface. Remote attackers who obtain this account can bypass IP access control restrictions and log in to the backend system without being recorded in the system logs. |
| Array Networks vAPV (version 8.3.2.17) and vxAG (version 9.2.0.34) appliances are affected by a privilege escalation vulnerability caused by a combination of hardcoded SSH credentials (or SSH private key) and insecure permissions on a startup script. The devices ship with a default SSH login or a hardcoded DSA private key, allowing an attacker to authenticate remotely with limited privileges.
Once authenticated, an attacker can overwrite the world-writable /ca/bin/monitor.sh script with arbitrary commands. Since this script is executed with elevated privileges through the backend binary, enabling the debug monitor via backend -c "debug monitor on" triggers execution of the attacker's payload as root. This allows full system compromise. |
| Zohocorp's ManageEngine Analytics Plus and Zoho Analytics on-premise versions older than 6130 are vulnerable to an AD only account takeover because of a hardcoded sensitive token. |
| INIM Electronics Smartliving SmartLAN/G/SI <=6.x contains hard-coded credentials in its Linux distribution image that cannot be changed through normal device operations. Attackers can exploit these persistent credentials to log in and gain unauthorized system access across multiple SmartLiving device models. |
| "Piccoma" App for Android and iOS versions prior to 6.20.0 uses a hard-coded API key for an external service, which may allow a local attacker to obtain the API key. Note that the users of the app are not directly affected by this vulnerability. |
| Use of a hard-coded password for a database administrator account created during Wapro ERP installation allows an attacker to retrieve embedded sensitive data stored in the database. The password is same among all Wapro ERP installations. This issue affects Wapro ERP Desktop versions before 8.90.0. |
| 'OfferBox' App for Android versions 2.0.0 to 2.3.17 and 'OfferBox' App for iOS versions 2.1.7 to 2.6.14 use a hard-coded secret key for JWT. Secret key for JWT may be retrieved if the application binary is reverse-engineered. |
| This vulnerability exists in Digisol DG-GR6821AC Router due to hard-coded Root Access Credentials in system configuration of the device firmware. An attacker with physical access could exploit this vulnerability by extracting the firmware and analyzing the binary data to obtain the stored root access credentials.
Successful exploitation of this vulnerability could allow the attacker to gain admin access to the targeted device. |
| Vue Vben Admin 2.10.1 allows unauthorized login to the backend due to an issue with hardcoded credentials. |
| A vulnerability in the .sdd file allows an attacker to read default passwords stored in plain text within the code. By exploiting these plaintext credentials, an attacker can log into affected SICK products as an “Authorized Client” if the customer has not changed the default password. |
| Use of Hard-coded Credentials vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5 and newer versions |
| Netis E1+ version 1.2.32533 contains a hardcoded root account vulnerability that allows unauthenticated attackers to access the device with predefined credentials. Attackers can leverage the embedded root account with a crackable password to gain full administrative access to the network device. |
| Precor touchscreen console P62, P80, and P82 contains a default SSH public key in the authorized_keys file. A remote attacker could use this key to gain root privileges. |