| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Use of Hard-coded Credentials in Kiloview NDI allows un-authenticated users to bypass authenticationThis issue affects Kiloview NDI N3, N3-s, N4, N20, N30, N40 and was fixed in Firmware version 2.02.0227 .
|
| An unauthenticated remote attacker can use hard-coded credentials to gain full administration privileges on the affected product. |
| An unauthenticated SQL injection vulnerability exists in Pandora FMS version 5.0 SP2 and earlier. The mobile/index.php endpoint fails to properly sanitize user input in the loginhash_data parameter, allowing attackers to extract administrator credentials or active session tokens via crafted requests. This occurs because input is directly concatenated into an SQL query without adequate validation, enabling SQL injection. After authentication is bypassed, a second vulnerability in the File Manager component permits arbitrary PHP file uploads. The file upload functionality does not enforce MIME-type or file extension restrictions, allowing authenticated users to upload web shells into a publicly accessible directory and achieve remote code execution. |
| Project AI is a platform designed to create AI agents. Prior to the pre-beta version, a hardcoded API key was present in the source code. This issue has been patched in the pre-beta version. |
| Use of Hard-coded Credentials vulnerability in ABB FLXEON.This issue affects FLXEON: through 9.3.5 and newer versions |
| An issue was discovered on ROADCAM X3 devices. The mobile app APK (Viidure) contains hardcoded FTP credentials for the FTPX user account, enabling attackers to gain unauthorized access and extract sensitive recorded footage from the device. |
| api is a module for FreePBX@, which is an open source GUI that controls and manages Asterisk© (PBX). In versions lower than 15.0.13, 16.0.2 through 16.0.14, 17.0.1 and 17.0.2, there is an identical OAuth private key used across multiple systems that installed the same FreePBX RPM or DEB package. An attacker with access to the shared OAuth private key could forge JWT tokens, bypass authentication, and potentially gain full access to both REST and GraphQL APIs. Systems with the "api" module enabled, configured and previously activated by an administrator for remote inbound connections may be affected. This issue is fixed in versions 15.0.13, 16.0.15 and 17.0.3. |
| SSL Pinning Bypass in eWeLink Some hardware products allows local ATTACKER to Decrypt TLS communication and Extract secrets to clone the device via Flash the modified firmware |
| Cypress Solutions CTM-200/CTM-ONE 1.3.6 contains hard-coded credentials vulnerability in Linux distribution that exposes root access. Attackers can exploit the static 'Chameleon' password to gain remote root access via Telnet or SSH on affected devices. |
| Quantum StorNext Web GUI API before 7.2.4 grants access to internal StorNext configuration and unauthorized modification of some software configuration parameters via undocumented user credentials. This affects StorNext RYO before 7.2.4, StorNext Xcellis Workflow Director before 7.2.4, and ActiveScale Cold Storage. |
| UNI-NMS-Lite uses hard-coded credentials that could allow an
unauthenticated attacker to read, manipulate and create entries in the
managed database. |
| The WP2Speed Faster – Optimize PageSpeed Insights Score 90-100 plugin for WordPress is vulnerable to unauthorized access in all versions up to, and including, 1.0.1. This is due to the use of hardcoded credentials to authenticate all the incoming API requests. This makes it possible for unauthenticated attackers to overwrite CSS, update the trial settings, purge the cache, and find attachments. |
| Use of Hard-coded Credentials vulnerability in Baicells Snap Router BaiCE_BMI on EP3011 (User Passwords modules) allows unauthorized access to the device. |
| hippo4j 1.0.0 to 1.5.0, uses a hard-coded secret key in its JWT (JSON Web Token) creation. This allows attackers with access to the source code or compiled binary to forge valid access tokens and impersonate any user, including privileged ones such as "admin". The vulnerability poses a critical security risk in systems where authentication and authorization rely on the integrity of JWTs. |
| Ever Traduora 0.20.0 and below is vulnerable to Privilege Escalation due to the use of a hard-coded JWT signing key. |
| Heatmiser Netmonitor 3.03 contains a hardcoded credentials vulnerability in the networkSetup.htm page with predictable admin login credentials. Attackers can access the device by using the hard-coded username 'admin' and password 'admin' in the hidden form input fields. |
| Neye3C v4.5.2.0 was discovered to contain a hardcoded encryption key in the firmware update mechanism. |
| It appears that some hardcoded keys are used for authentication to internal API. Knowing these private keys may allow attackers to bypass authentication and reach administrative interfaces. As for the affected products/models/versions, see the reference URL. |
| all the Toshiba printers have programs containing a hardcoded key used to encrypt files. An attacker can decrypt the encrypted files using the hardcoded key. Insecure algorithm is used for the encryption. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.
https://www.toshibatec.com/contacts/products/
As for the affected products/models/versions, see the reference URL. |
| All the Toshiba printers contain a shell script using the same hardcoded key to encrypt logs. An attacker can decrypt the encrypted files using the hardcoded key. This vulnerability can be executed in combination with other vulnerabilities and difficult to execute alone. So, the CVSS score for this vulnerability alone is lower than the score listed in the "Base Score" of this vulnerability. For detail on related other vulnerabilities, please ask to the below contact point.
https://www.toshibatec.com/contacts/products/
As for the affected products/models/versions, see the reference URL. |