| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| Vulnerability in the Oracle Payroll product of Oracle E-Business Suite (component: Self Service Manager). Supported versions that are affected are 12.2.3-12.2.15. Easily exploitable vulnerability allows low privileged attacker with network access via HTTP to compromise Oracle Payroll. Successful attacks of this vulnerability can result in takeover of Oracle Payroll. CVSS 3.1 Base Score 8.8 (Confidentiality, Integrity and Availability impacts). CVSS Vector: (CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). |
| OpenClaude is an open-source coding-agent command line interface for cloud and local model providers. Prior to version 0.5.1, the dangerouslyDisableSandbox parameter is exposed as part of the BashTool input schema, meaning the LLM (an untrusted principal per the project's own threat model) can set it to true in any tool_use response. Combined with the default allowUnsandboxedCommands: true setting, a prompt-injected model can escape the sandbox for any arbitrary command, achieving full host-level code execution. This issue has been patched in version 0.5.1. |
| Missing Authentication for Critical Function vulnerability in EMTA Grup PDKS allows Exploiting Incorrectly Configured Access Control Security Levels.
This issue affects PDKS: from V3.04 before 20240603. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. |
| Missing Authentication, Files or Directories Accessible to External Parties, Use of Hard-coded Credentials vulnerability in Talya Informatics Elektraweb allows Authentication Bypass.
This issue affects Elektraweb: before v17.0.68. |
| Missing Authentication for Critical Function, Missing Authorization vulnerability in Menulux Information Technologies Managment Portal allows Collect Data as Provided by Users.
This issue affects Managment Portal: through 21.05.2024. |
| A security vulnerability has been detected in nextlevelbuilder GoClaw up to 3.11.3. This affects the function resolveAuth of the file internal/http/auth.go of the component Webhook Verification Handler. The manipulation leads to missing authentication. Remote exploitation of the attack is possible. The exploit has been disclosed publicly and may be used. The project tagged the reported issue as bug. |
| Missing Authentication for Critical Function, Missing Authorization vulnerability in Yordam Information Technology Mobile Library Application allows Retrieve Embedded Sensitive Data.
This issue affects Mobile Library Application: before 5.0. |
| The default configuration of Crimson 3.1 (Build versions prior to 3119.001) allows a user to be able to read and modify the database without authentication. |
| Multiple Phoenix Contact devices allow remote attackers to establish TCP sessions to port 1962 and obtain sensitive information or make changes, as demonstrated by using the Create Backup feature to traverse all directories. |
| Missing authentication and clear‑text transmission of data from the heat pumps to the control server, combined with the absence of input validation on aggregated data, can lead to stored XSS that enables theft of cookies from the pump’s web control interface. Older Orca heat pump devices communicating with the Orca server over an
unencrypted and unauthenticated HTTP connection on a non-secure port specifically enable an
attacker to impersonate a legitimate device and inject malicious
payloads. This enables the insertion of harmful code directly
into the Orca user portal, potentially compromising user accounts,
exposing sensitive information, and allowing further unauthorized
actions within the portal. |
| Spacelabs Healthcare Sentinel versions 10.5.x and higher and 11.x.x before 11.6.0 contain an unauthenticated remote code execution vulnerability through a deprecated .NET Remoting HTTP channel exposed on port 8989 that allows attackers to perform arbitrary file read and write operations by supplying valid .NET URI endpoints. Attackers can write ASPX webshells to the IIS wwwroot directory to achieve unauthenticated remote code execution on the system. Port 8989 is not exposed in a default Sentinel installation; exploitation requires that the .NET Remoting port has been explicitly made network-accessible through deliberate configuration or network policy changes. |
| An issue was discovered in Moxa NPort 5110 versions prior to 2.6, NPort 5130/5150 Series versions prior to 3.6, NPort 5200 Series versions prior to 2.8, NPort 5400 Series versions prior to 3.11, NPort 5600 Series versions prior to 3.7, NPort 5100A Series & NPort P5150A versions prior to 1.3, NPort 5200A Series versions prior to 1.3, NPort 5150AI-M12 Series versions prior to 1.2, NPort 5250AI-M12 Series versions prior to 1.2, NPort 5450AI-M12 Series versions prior to 1.2, NPort 5600-8-DT Series versions prior to 2.4, NPort 5600-8-DTL Series versions prior to 2.4, NPort 6x50 Series versions prior to 1.13.11, NPort IA5450A versions prior to v1.4. Firmware can be updated over the network without authentication, which may allow remote code execution. |
| A vulnerability has been identified in SIMATIC HMI Comfort Panels (incl. SIPLUS variants) (All versions < V16 Update 3a), SIMATIC HMI KTP Mobile Panels (All versions < V16 Update 3a), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). Affected devices with enabled telnet service do not require authentication for this service. This could allow a remote attacker to gain full access to the device. (ZDI-CAN-12046) |
| The locally served web site on the Garmin WDU (v1 1.4.6 and v2 5.0) allows its authentication to be bypassed. The WDU web site only performs authentication with the client within the client's browser. The WebSockets used to communicate with the WDU server do not enforce any authentication. An attacker may bypass all authentication mechanisms by directly utilizing the remote APIs available on the websocket. |
| Cr*nMaster (cronmaster) is a Cronjob management UI with human readable syntax, live logging and log history for cronjobs. Prior to version 2.2.0, an authentication bypass in middleware allows unauthenticated requests with an invalid session cookie to be treated as authenticated when the middleware’s session-validation fetch fails. This can result in unauthorized access to protected pages and unauthorized execution of privileged Next.js Server Actions. This issue has been patched in version 2.2.0. |
| Cryptographic Issue while processing a specific partition which allows unauthorized write access to load a customized bootloader. |
| Cryptographic issue while processing partition table entries allows unauthorized modification of boot flow. |
| This vulnerability allows remote attackers to execute arbitrary code on affected installations of BMC Track-It! 20.21.2.109. Authentication is not required to exploit this vulnerability. The specific flaw exists within the authorization of HTTP requests. The issue results from the lack of authentication prior to allowing access to functionality. An attacker can leverage this vulnerability to execute code in the context of the service account. Was ZDI-CAN-16709. |
| A vulnerability was detected in Bottelet DaybydayCRM up to 2.2.1. Affected is an unknown function of the component Setting Handler. Performing a manipulation results in missing authentication. Remote exploitation of the attack is possible. It is recommended to apply a patch to fix this issue. |
| Missing Authentication for Critical Function, Missing Authorization vulnerability in Nomysoft Informatics Nomysem allows Collect Data as Provided by Users.
This issue affects Nomysem: before 13.10.2024. |