| CVE |
Vendors |
Products |
Updated |
CVSS v3.1 |
| The embedded web server on the thermostat listed version ranges contain a vulnerability that allows unauthenticated attackers, either on the local area network or from the Internet via a router with port forwarding set up, to gain direct access to the thermostat's embedded web server and reset user credentials by manipulating specific elements of the embedded web interface. |
| The exos 9300 application can be used to configure Access Managers (e.g. 92xx, 9230 and 9290). The configuration is done in a graphical user interface on the dormakaba exos server. As soon as the save button is clicked in exos 9300, the whole configuration is sent to the selected Access Manager via SOAP. The SOAP request is sent without any prior authentication or authorization by default. Though authentication and authorization can be configured using IPsec for 92xx-K5 devices and mTLS for 92xx-K7 devices, it is not enabled by default and must therefore be activated with additional steps.
This insecure default allows an attacker with network level access to completely control the whole environment. An attacker is for example easily able to conduct the following tasks without prior authentication:
- Re-configure Access Managers (e.g. remove alarming system requirements)
- Freely re-configure the inputs and outputs
- Open all connected doors permanently
- Open all doors for a defined time interval
- Change the admin password
- and many more
Network level access can be gained due to an insufficient network segmentation as well as missing LAN firewalls. Devices with an insecure configuration have been identified to be directly exposed to the internet. |
| Improper handling of WiFi information by framework services can allow certain malicious applications to obtain sensitive information. |
| Missing Authentication for Critical Function vulnerability in ABB ABB AbilityTM zenon.This issue affects ABB AbilityTM zenon: from 7.50 through 14. |
| Missing Authentication for Critical Function vulnerability in NEC Corporation Aterm WG2600HS Ver.1.7.2 and earlier, WF1200CRS Ver.1.6.0 and earlier, WG1200CRS Ver.1.5.0 and earlier, GB1200PE Ver.1.3.0 and earlier, WG2600HP4 Ver.1.4.2 and earlier, WG2600HM4 Ver.1.4.2 and earlier, WG2600HS2 Ver.1.3.2 and earlier, WX3000HP Ver.2.4.2 and earlier and WX4200D5 Ver.1.2.4 and earlier allows a attacker to get a Wi-Fi password via the network. |
| The database for the web application is exposed without authentication, allowing an unauthenticated remote attacker to gain unauthorized access and potentially compromise it. |
| Karapace is an open-source implementation of Kafka REST and Schema Registry. Versions 5.0.0 and 5.0.1 contain an authentication bypass vulnerability when configured to use OAuth 2.0 Bearer Token authentication. If a request is sent without an Authorization header, the token validation logic is skipped entirely, allowing an unauthenticated user to read and write to Schema Registry endpoints that should otherwise be protected. This effectively renders the OAuth authentication mechanism ineffective. This issue is fixed in version 5.0.2. |
| Denver SHO-110 IP cameras expose a secondary HTTP service on TCP port 8001 that provides access to a '/snapshot' endpoint without authentication. While the primary web interface on port 80 enforces authentication, the backdoor service allows any remote attacker to retrieve image snapshots by directly requesting the 'snapshot' endpoint. An attacker can repeatedly collect snapshots and reconstruct the camera stream, compromising the confidentiality of the monitored environment. |
| PLANEX CS-QP50F-ING2 smart cameras expose a configuration backup interface over HTTP that does not require authentication. A remote, unauthenticated attacker can directly retrieve a compressed configuration backup file from the device. The backup contains sensitive configuration information, including credentials, allowing an attacker to obtain administrative access to the camera and compromise the confidentiality of the monitored environment. |
| Seeyon Zhiyuan OA Web Application System versions up to and including 7.0 SP1 improperly decode and parse the `enc` parameter in thirdpartyController.do. The decoded map values can influence session attributes without sufficient authentication/authorization checks, enabling attackers to assign a session to arbitrary user IDs. VulnCheck has observed this vulnerability being exploited in the wild as of 2025-10-30 at 00:30:40.855917 UTC. |
| In the moPS App through 1.8.618, all users can access administrative API endpoints without additional authentication, resulting in unrestricted read and write access, as demonstrated by /api/v1/users/resetpassword. |
| Traq versions 2.0 through 2.3 contain a remote code execution vulnerability in the admincp/common.php script. The flawed authorization logic fails to halt execution after a failed access check, allowing unauthenticated users to reach admin-only functionality. This can be exploited via plugins.php to inject and execute arbitrary PHP code. |
| The endpoint hosts a script that allows an unauthorized remote attacker to put the system in a fail-safe state over the network due to missing authentication. |
| A vulnerability was found in eGauge EG3000 Energy Monitor 3.6.3. It has been classified as problematic. This affects an unknown part of the component Setting Handler. The manipulation leads to missing authentication. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| A vulnerability classified as problematic was found in Lucky LM-520-SC, LM-520-FSC and LM-520-FSC-SAM up to 20250321. Affected by this vulnerability is an unknown functionality. The manipulation leads to missing authentication. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way. |
| Telesquare SKT LTE Router SDT-CS3B1 software version 1.2.0 contains an unauthenticated remote reboot vulnerability that allows attackers to trigger device reboot without authentication. Attackers can send POST requests to the lte.cgi endpoint with the Command=Reboot parameter to cause denial of service by forcing the router to restart. |
| A missing authentication for critical function vulnerability has been reported to affect QVR Pro. The remote attackers can then exploit the vulnerability to gain access to the system.
We have already fixed the vulnerability in the following version:
QVR Pro 2.7.4.14 and later |
| OneUptime is an open-source monitoring and observability platform. Prior to version 10.0.42, the Worker service's ManualAPI exposes workflow execution endpoints (GET /workflow/manual/run/:workflowId and POST /workflow/manual/run/:workflowId) without any authentication middleware. An attacker who can obtain or guess a workflow ID can trigger arbitrary workflow execution with attacker-controlled input data, enabling JavaScript code execution, notification abuse, and data manipulation. This issue has been patched in version 10.0.42. |
| Missing authentication for critical function in Azure IoT Explorer allows an unauthorized attacker to disclose information over a network. |
| A low-privileged remote attacker can send Modbus packets to manipulate
register values that are inputs to the odorant injection logic such that
too much or too little odorant is injected into a gas line. |