In the Linux kernel, the following vulnerability has been resolved:
iommu/vt-d: Fix iopf_refcount leak on RID domain replacement
intel_iommu_attach_device() enables IOPF for the new domain but never
disables it for the old one. device_block_translation(), called at the
start of the function, tears down translation but does not touch any IOPF
state; blocking_domain_attach_dev() has to call iopf_for_domain_remove()
explicitly before invoking it for exactly this reason.
identity_domain_attach_dev() has the same problem. Its comment claims
that no PRI handling is needed because the device has been put in the
blocking state, but the blocking state and the IOPF reference count are
independent of each other.
As a result, replacing a domain that has an iopf_handler with another
domain at RID level leaks a reference in info->iopf_refcount. The count
never drops back to zero, so iopf_queue_remove_device() is never called
and iommu_disable_pci_pri() triggers its WARN_ON(info->iopf_refcount)
when the device is released.
The PASID paths already handle this correctly by way of
iopf_for_domain_replace(); convert the two RID paths to do the same.
Using the replace helper rather than a bare remove keeps the enable
before the disable, so the reference count does not transiently reach
zero and evict the device from the IOPF queue.
iommu/vt-d: Fix iopf_refcount leak on RID domain replacement
intel_iommu_attach_device() enables IOPF for the new domain but never
disables it for the old one. device_block_translation(), called at the
start of the function, tears down translation but does not touch any IOPF
state; blocking_domain_attach_dev() has to call iopf_for_domain_remove()
explicitly before invoking it for exactly this reason.
identity_domain_attach_dev() has the same problem. Its comment claims
that no PRI handling is needed because the device has been put in the
blocking state, but the blocking state and the IOPF reference count are
independent of each other.
As a result, replacing a domain that has an iopf_handler with another
domain at RID level leaks a reference in info->iopf_refcount. The count
never drops back to zero, so iopf_queue_remove_device() is never called
and iommu_disable_pci_pri() triggers its WARN_ON(info->iopf_refcount)
when the device is released.
The PASID paths already handle this correctly by way of
iopf_for_domain_replace(); convert the two RID paths to do the same.
Using the replace helper rather than a bare remove keeps the enable
before the disable, so the reference count does not transiently reach
zero and evict the device from the IOPF queue.
Advisories
No advisories yet.
Fixes
Solution
No solution given by the vendor.
Workaround
No workaround given by the vendor.
References
History
Thu, 17 Sep 2026 16:30:00 +0000
| Type | Values Removed | Values Added |
|---|---|---|
| Description | In the Linux kernel, the following vulnerability has been resolved: iommu/vt-d: Fix iopf_refcount leak on RID domain replacement intel_iommu_attach_device() enables IOPF for the new domain but never disables it for the old one. device_block_translation(), called at the start of the function, tears down translation but does not touch any IOPF state; blocking_domain_attach_dev() has to call iopf_for_domain_remove() explicitly before invoking it for exactly this reason. identity_domain_attach_dev() has the same problem. Its comment claims that no PRI handling is needed because the device has been put in the blocking state, but the blocking state and the IOPF reference count are independent of each other. As a result, replacing a domain that has an iopf_handler with another domain at RID level leaks a reference in info->iopf_refcount. The count never drops back to zero, so iopf_queue_remove_device() is never called and iommu_disable_pci_pri() triggers its WARN_ON(info->iopf_refcount) when the device is released. The PASID paths already handle this correctly by way of iopf_for_domain_replace(); convert the two RID paths to do the same. Using the replace helper rather than a bare remove keeps the enable before the disable, so the reference count does not transiently reach zero and evict the device from the IOPF queue. | |
| Title | iommu/vt-d: Fix iopf_refcount leak on RID domain replacement | |
| First Time appeared |
Linux
Linux linux Kernel |
|
| CPEs | cpe:2.3:o:linux:linux_kernel:*:*:*:*:*:*:*:* | |
| Vendors & Products |
Linux
Linux linux Kernel |
|
| References |
|
Projects
Sign in to view the affected projects.
Status: PUBLISHED
Assigner: Linux
Published:
Updated: 2026-09-17T16:07:45.817Z
Reserved: 2026-09-11T19:38:34.795Z
Link: CVE-2026-90242
No data.
Status : Received
Published: 2026-09-17T17:17:20.190
Modified: 2026-09-17T17:17:20.190
Link: CVE-2026-90242
No data.
OpenCVE Enrichment
No data.
Weaknesses
No weakness.