Export limit exceeded: 20936 CVEs match your query. Please refine your search to export 10,000 CVEs or fewer.

Search

Search Results (20936 CVEs found)

CVE Vendors Products Updated CVSS v3.1
CVE-2025-26055 2026-04-15 6.5 Medium
An OS Command Injection vulnerability exists in the Infinxt iEdge 100 2.1.32 Troubleshoot module, specifically in the tracertVal parameter of the Tracert function.
CVE-2024-7137 2026-04-15 6.5 Medium
The L2CAP receive data buffer for L2CAP packets is restricted to packet sizes smaller than the maximum supported packet size. Receiving a packet that exceeds the restricted buffer length may cause a crash. A hard reset is required to recover the crashed device.
CVE-2025-8697 2026-04-15 6.3 Medium
A vulnerability was found in agentUniverse up to 0.0.18 and classified as critical. This issue affects the function StdioServerParameters of the component MCPSessionManager/MCPTool/MCPToolkit. The manipulation leads to os command injection. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
CVE-2024-7139 2026-04-15 6.5 Medium
Due to an unchecked buffer length, a specially crafted L2CAP packet can cause a buffer overflow. This buffer overflow triggers an assert, which results in a temporary denial of service.  If a watchdog timer is not enabled, a hard reset is required to recover the device.
CVE-2024-11983 1 Billion Electric 4 M100, M120n, M150 and 1 more 2026-04-15 7.2 High
Certain models of routers from Billion Electric has an OS Command Injection vulnerability, allowing remote attackers with administrator privileges to inject arbitrary system commands into a specific SSH function and execute them on the device.
CVE-2025-5943 1 Microdicom 1 Dicom Viewer 2026-04-15 8.8 High
MicroDicom DICOM Viewer suffers from an out-of-bounds write vulnerability. Remote attackers are able to exploit this issue to potentially execute arbitrary code on affected installations of DICOM Viewer. User interaction is required to exploit the vulnerability in that the user must either visit a malicious website or open a malicious DICOM file locally.
CVE-2025-59370 1 Asus 1 Router 2026-04-15 N/A
A command injection vulnerability has been identified in bwdpi. A remote, authenticated attacker could leverage this vulnerability to potentially execute arbitrary commands, leading to the device executing unintended instructions. Refer to the 'Security Update for ASUS Router Firmware' section on the ASUS Security Advisory for more information.
CVE-2025-59366 1 Asus 1 Router 2026-04-15 N/A
An authentication-bypass vulnerability exists in AiCloud. This vulnerability can be triggered by an unintended side effect of the Samba functionality, potentially leading to allow execution of specific functions without proper authorization. Refer to the Security Update for ASUS Router Firmware section on the ASUS Security Advisory for more information.
CVE-2024-43656 2026-04-15 8.8 High
Improper Neutralization of Special Elements used in a Command ('Command Injection') vulnerability allows OS Command Injection as root This issue affects Iocharger firmware for AC model chargers before version 24120701. Likelihood: Moderate – It might be difficult for an attacker to identify the file structure of the <redated> directory, and then modify the backup to add a new CGI script in the correct directory. Furthermore, the attacker will need an account to restore the settings backup, or convince a user with such access to upload a modified backup file. Impact: Critical – The attacker has full control over the charging station as the root user, and can arbitrarily add, modify and deletefiles and services. CVSS clarification: Any network interface serving the web ui is vulnerable (AV:N) and there are not additional security measures to circumvent (AC:L), nor does the attack require and existing preconditions (AT:N). The attack is authenticated, but the level of authentication does not matter (PR:L), nor is any user interaction required (UI:N). The attack leads to a full compromised (VC:H/VI:H/VA:H), and compromised devices can be used to pivot into networks that should potentially not be accessible (SC:L/SI:L/SA:H). Becuase this is an EV charger handing significant power, there is a potential safety impact (S:P). This attack can be automated (AU:Y).
CVE-2024-1628 2026-04-15 8.4 High
OS command injection vulnerabilities in GE HealthCare ultrasound devices
CVE-2024-3799 2026-04-15 N/A
Insecure handling of POST header parameter body included in requests being sent to an instance of the open-source project Phoniebox allows an attacker to create a website, which – when visited by a user – will send malicious requests to multiple hosts on the local network. If such a request reaches the server, it will cause a shell command execution. This issue affects Phoniebox in all releases through 2.7. Newer 2.x releases were not tested, but they might also be vulnerable. Phoniebox in version 3.0 and higher are not affected.
CVE-2025-2071 2026-04-15 N/A
A critical OS Command Injection vulnerability has been identified in the FAST LTA Silent Brick WebUI, allowing remote attackers to execute arbitrary operating system commands via specially crafted input. This vulnerability arises due to improper handling of untrusted input, which is passed directly to system-level commands without adequate sanitization or validation. Successful exploitation could allow attackers to execute arbitrary commands on the affected system, potentially resulting in unauthorized access, data leakage, or full system compromise. Affected WebUI parameters are "hd" and "pi".
CVE-2024-38510 1 Lenovo 1 Xclarity Controller 2026-04-15 7.2 High
A privilege escalation vulnerability was discovered in the SSH captive command shell interface that could allow an authenticated XCC user with elevated privileges to perform command injection via specially crafted file uploads.
CVE-2024-38511 2026-04-15 7.2 High
A privilege escalation vulnerability was discovered in an upload processing functionality of XCC that could allow an authenticated XCC user with elevated privileges to perform command injection via specially crafted file uploads.
CVE-2024-38512 1 Lenovo 1 Xclarity Controller 2026-04-15 7.2 High
A privilege escalation vulnerability was discovered in XCC that could allow an authenticated XCC user with elevated privileges to perform command injection via specially crafted IPMI commands.
CVE-2024-38533 1 Matter-labs 1 Era-compiler-vyper 2026-04-15 6.5 Medium
ZKsync Era is a layer 2 rollup that uses zero-knowledge proofs to scale Ethereum. There is possible invalid stack access due to the addresses used to access the stack not properly being converted to cells. This issue has been patched in version 1.5.0.
CVE-2024-39251 1 Thunderobot 1 Control Center 2026-04-15 10 Critical
An issue in the component ControlCenter.sys/ControlCenter64.sys of ThundeRobot Control Center v2.0.0.10 allows attackers to access sensitive information, execute arbitrary code, or escalate privileges via sending crafted IOCTL requests.
CVE-2025-20161 2026-04-15 5.1 Medium
A vulnerability in the software upgrade process of Cisco Nexus 3000 Series Switches and Cisco Nexus 9000 Series Switches in standalone NX-OS mode could allow an authenticated, local attacker with valid Administrator credentials to execute a command injection attack on the underlying operating system of an affected device. This vulnerability is due to insufficient validation of specific elements within a software image. An attacker could exploit this vulnerability by installing a crafted image. A successful exploit could allow the attacker to execute arbitrary commands on the underlying operating system with root privileges.&nbsp; Note: Administrators should validate the hash of any software image before installation.
CVE-2025-20055 2026-04-15 9.8 Critical
OS command injection vulnerability exists in network storage servers STEALTHONE D220/D340 provided by Y'S corporation. An attacker who can access the affected product may execute an arbitrary OS command.
CVE-2025-3128 1 Mitsubishielectric 1 Smartrtu 2026-04-15 9.8 Critical
A remote unauthenticated attacker who has bypassed authentication could execute arbitrary OS commands to disclose, tamper with, destroy or delete information in Mitsubishi Electric smartRTU, or cause a denial-of service condition on the product.